  • VIPA SPEED7    >>   S7-300® and S7-400® system solutions

    CPU's  Programmed by STEP®7 from Siemens

    SPEED7, programmed by STEP®7 from Siemens.  

    • S7-400® instruction set solution
    • Programmable with all languages, LAD, FBD, STL, SCL, CFC, Graph7
    • Flexible Memory architecture from 64kB to 16MB, upgradable at any time via VIPA MMC
    • SPEED-Bus backplane to the left of the CPU for high speed requirments
    • Up to 32 VIPA 300V modules and 16 SPEED modules connectable in one line
    • Profibus DP onboard CPU
    • TCP/IP on board CPU
    • MPI port onboard CPU
    • Faster SCAN time - up to 10x faster than a S7-400®
    • More memory - up to 4MByte !
    • MMC standard memory card for complete project / program backup
    • No MMC required for load memory, built in

    See above menu for a full list of all digital and analogue modules for the SPEED7®.    

    This is your lowest cost option in Australia for S7-400® solutions. 

    Don't own the software?..   that's OK,  we also supply Programming software ..  click here  

    How Fast is the SPEED7 ?

     

    • 315 SB/DPM CPU with DP Master, TCP/IP 128KB-1MB
    • 315 SN/DPM CPU with DP Master, CP343-1 TCP/IP 128KB-1MB
    • 314 ST/DPM CPU with DP Master, TCP/IP, SPEED-Bus 64kB-1MB
    • 317 SE/DPM CPU with DP Master, TCP/IP, SPEED-Bus, USB-B, 512KB-4MB
    • 317 SN/DPM CPU with CP Master, CP343-1 TCP/IP 512KB-4MB

     

    Technical Data 315 SB/DPM 315 SN/DPM 314 ST/DPM 317 SE/DPM 317 SN/DPM
      ........................... ........................... .......................... ........................... ...........................
    Supply voltage 24Vdc 24Vdc 24Vdc 24Vdc 24Vdc
    Memory
      128kB - 1MB 128kB - 1MB 64kB - 1MB 512kB - 4MB 512kB - 4MB
               
    Battery Buffer / clock Yes Yes Yes Yes Yes
    Flags, Byte 8192Byte 8192Byte 8192Byte 8192Byte 8192Byte
    Data Blocks 4096 4096 4096 4096 4096
    Timers (Siemens) 512 512 512 512 512
    Timers ( IEC ) Limited only by Memory Limited only by Memory Limited only by Memory Limited only by Memory Limited only by Memory
    Counters (Siemens) 512 512 512 512 512
    Counters ( IEC ) Limited only by Memory Limited only by Memory Limited only by Memory Limited only by Memory Limited only by Memory
    Modules per CPU 32 single or multi-line plus 16 modules SPEED-Bus 32 single or multi-line plus 16 modules SPEED-Bus 32 single or multi-line plus 16 modules SPEED-Bus 32 single or multi-line plus 16 modules SPEED-Bus 32 single or multi-line plus 16 modules SPEED-Bus
    Total address I/O 8192 / 8192Byte 8192 / 8192Byte 8192 / 8192Byte 8192 / 8192Byte 8192 / 8192Byte
    Process Image I/O 2048/2048Byte 2048/2048Byte 2048/2048Byte 2048/2048Byte 2048/2048Byte
    Processing Time      
    / kbits 0.014ms 0.014ms 0.014ms 0.014ms 0.014ms
    / kwords 0.014ms 0.014ms 0.014ms 0.014ms 0.014ms
    Interfaces
    MPI yes yes yes yes yes
    DP Master yes yes yes yes yes
    TCP/IP 2 connections- SCADA, Programming, XGET-XPUT yes yes yes yes yes
    CP343 - TCP/IP via STEP7 - 16 connections -- yes -- -- yes
    SPEED-Bus -- -- yes yes yes
    CANopen optional optional optional optional optional