| | Login |
|
|
|
Click for Partno list
TB20 Analogue I/O AI 2xTC Iso 16bit AI 2xV 16Bit iso AI 4xI 12Bit AI 4xI Iso 16bit AI 4xV 12Bit AI 8xI Iso 16bit AI 8xTC Iso 16bit AO 4xI 12Bit AO 4xV 12Bit Automation Warehouse Ph: 0734880177 email: click |
|
AI 4xI Iso 16bit
Part Number: 600-250-7BD01 Description: 4 Analogue inputs Current Isolated AI 4 x I, 0/4-20 mA, ±20 mA, Iso., 16 Bit Parameters for the module • Diagnostic alarm: On | Off • Overflow / underflow diagnosis: On | Off • Representation values: SIMATIC* S7 | SIMATIC* S5 Parameters for each channel • Wire break detection (only for 4 ... 20 mA): On | Off • Interference frequency suppression: None | 10 Hz | 50 Hz | 60 Hz | 400 Hz • Measuring ranges: Deactivated | 0 ... 20 mA | 4 ... 20 mA | ±20 mA • Limit value alarms enabled: On | Off • Upper/lower limit: 16 bit analog value (±27648) Channel LED signals Flashing red light - Parameter assignment error on channel Solid red light - Reading overflow/underflow or wire break Flashing green light - Reading within overrange Solid green light - Channel configured, normal reading Off - Channel disabled or module not yet configured • Channels electrically isolated from each other and from the backplane bus • Measuring ranges 0 ... 20 mA, 4 ... 20 mA, ±20 mA, individually configurable for each channel • Measurement resolution: up to 15 bits + sign • Diagnostic messages • Wire break detection (for 4 ... 20 mA) • Limit value alarms for each channel • A bi-color LED (blue/red) indicates the module operating status and any malfunctions • Red/green bi-color LEDs (one for each channel) indicate the channel status • 4 analog inputs for measuring current • 4 process input words General information Dimensions (DxWxH) 110 x 14 x 73 mm Weight Approx. 80g Number of inputs 4 Electrical isolation from the backplane bus Electrical isolation Between the channels Current draw Internal Max. 140 mA Power dissipation Max. 1 W Measuring ranges / load resistance 0 ... 20 mA / 50 ohms, 4 ... 20 mA / 50 ohms, ±20 mA / 50 ohms Measuring method - Integration Measurement resolution 15 bits + sign Interference frequency suppression - None | 10 Hz | 50 Hz | 60 Hz | 400 Hz Refresh rate / conversion rate: The conversion time will depend on the interference frequency suppression: None: 2.5 ms, 400 Hz: 8 ms, 60 Hz: 51 ms, 50 Hz: 60 ms, 10 Hz: 160 ms Diagnoses - Upper measuring range limit exceeded (overflow), lower measuring range limit fallen below (underflow), wire break (for 4 ... 20 mA only), parameter assignment error Process alarms - Upper and lower limit per channel Error limits Operational error limit in the entire temperature range ±0.2 % relative to the nominal range Basic error limit at 25 °C > ±0.1 % relative to the nominal range Temperature error > ±0.005 %/K relative to the nominal range Linearity error > ±0.05 %/K relative to the nominal range Repeating accuracy in steady state at 25 °C > ±0.05 %/K relative to the nominal range Parameter configuration length - 24 Bytes General error indicator - Red LED Hot-swap capable - Yes Ambient temperature - 0 °C … +60 °C Transport and storage temperature -20 °C … +80 °C Relative air humidity - 95 % r H without condensation Protection rating -IP 20 Certifications - CE, UL Surrounding Air Temperature - 0 °C … +60°C Noise immunity - DIN EN 61000-6-2 EMC Immunity Interference emission DIN EN 61000-6-4 EMC Emission Vibration and shock resistance DIN EN 60068-2-8:2008 Vibration, DIN EN 60068-27:2010 Shock
|
||||||||||||